    A study on safety, complications and expulsion rates of immediate post placental insertion of IUCD


    Dr. Laxmi Itagi, Dr. Syeda Zohra Jabeen, Dr. Harini R
    JCDR. 2023: 262-265

    Abstract

    The current national strategy in India is for increasing IUCD uptake. The available target to cover with PPIUCD as a method of contraception has expanded in the recent past; since there is a 10 fold increase in women delivering in hospitals due to maternity benefit scheme. On reviewing the literature little Indian data and few studies were found regarding post placental insertion of IUCD. The copper T was inserted with all aseptic precautions within 10 minutes of placental expulsion with Kelly’s forceps. Strings cut to the level of the cervix (In Cu T 375 where thread is long, compared to Cu T 380 A). Proper placement in the uterine cavity was confirmed by ultrasound at 6 weeks Post placental delivery insertion of PPIUCD. Study observed that; in majority of patients i.e. 75 (75.0%) Cu T thread was noted and in 22 (22.0%) of patients Cu T thread was not seen on per speculum examination. Expulsion was seen in 4% of patients, one patient expelled on POD 2, one patient expelled on POD 18 and two patients expelled at 6 weeks. In expelled patients there were 3 Multipara’s and 1 primipara. Pelvic pain was seen in 8 (8.0%) patients-caesarean 4, vaginal 4 and perforation was not seen in of the patients.